Conductor: Flexible polished copper rope class V s/. UNE-EN 60228.
Insulation: EN 50363-1 - Ethylene propylene rubber type EI-6.
Identification: HD 308 S2
Assembly: Concentrically wired insulated conductors.
Outer cover: EN 50363-10-2 - Thermoplastic Polyurethane (TPU) compound.
Color: Orange
Operating voltage: 450/750V
Test voltage: 2.500V 5min
Operating temperature: -40...+90ºC (250ºC / 5 segundos en cortocircuito)
Standards:
(Construction) UNE-EN 50525-2-21 - General purpose cables. Flexible cables with cross-linked elastomer insulation.
(Insulation) EN 50363-1 - Ethylene propylene rubber type EI-6.
(Sheath) EN 50363-10-2 - Thermoplastic Polyurethane (TPU) compound.
Cables with AD7 level, submersible.
Flexible cables suitable for mobile use with EPR insulation and polyurethane sheath, for demanding services in dry, humid or wet locations. Suitable for use in industrial and agricultural workshops, buildings, applications and power supply of appliances for demanding services where cables are subjected to medium mechanical stresses (examples: heating plates, portable lamps, electrical tools such as drills, circular saws and household power tools).
Fill in the following fields to request the cable technical sheet in PDF format and the Declaration of Performance (DOP)