Central Element: Central element (Glass Reinforced Plastic)
Fibres Nb: 24
Identification: According to TIA/EIA 598A and IEC 304.
Assembly: Tubes filled with thixotropic gel.
Armour: WB reinforced fibreglass fillings (waterblocking)
Outer cover: UNE-EN 50290-2-24 - Polyethylene for outer sheaths.
Color: Black
CPR classification: Fca
Operating temperature: -40... +70ºC
Standards:
(Sheath) UNE-EN 50288-7 - Instrumentation and control cables. / UNE-EN 50290-2-24 - Polyethylene for outer sheaths.
(Fire) UNE-EN 50575 - CPR
(Fire) UNE-EN 60754-2 (IEC 60754-2) - Low corrosivity of smoke.
(Fire) UNE-EN 61034 (IEC 61034) - Low smoke emission.
(Fire) UNE-EN 60754-1 (IEC 60754-1) - Halogen-free.
(Tests) IEC 60794-1-22 - Environmental tests on FO cables.
(Tests) IEC 60794-1-21 - Mechanical tests on FO cables.
(Tests) IEC 60794-1 - Basic test procedures for optical cables.
(Directives) 2011/65/EU - RoHS Directive (No use of toxic products).
(System) ISO/IEC 11801 Edition 2 - Information technology -- Generic cabling.
(System) UNE-EN 50173-1 - Information technology - Generic cabling systems - Part 1: General requirements.
(System) TIA/EIA 568C - Structured Cabling System
Fiber color code:
Up to 12 fibers: Red-Green-Blue-Yellow-Grey-Violet-Brown-Orange-White-Pink-Black-Turquoise.
Between 13 and 24 fibers: Same as 12 fibers with black rings.
Tube color code:
Red-Green-Natural-...-Natural. Passive tubes in black color.
Jelly-filled, single loose tube fibre optic cable with dielectric armour for outdoor installations.
Cables of up to 576 fibers,with fibre glass reinforcement and Polietilene outer sheath.
Small Rodents resistant.