Conductor: Solid Bare Copper AWG24.
Insulation: UNE-EN 50290-2-23 - Polyethylene for insulation.
Identification: White/Brown-Brown, White/Orange-Orange, White/Green-Green, White / Blue - Blue
Assembly: Pairs
Protector: Polyester ribbon.
Overall Shielding Al/Pet: Aluminium/Polyester Tape.
Overall Drain wire: Solid tinned copper AWG24.
Braid Shielding: Cu Sn braid screen.
Outer cover: UNE-EN 50290-2-27 - Halogen-free Z1 compound.
Color: Grey RAL-7035
CPR classification: Dca-s2, d2, a2
Operating voltage: 100/100V
Test voltage: 1000 V
Operating temperature: -15... +70ºC
Standards:
(Construction) IEC-61156-5 - Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Horizontal floor wiring - Sectional specification
(Construction) UNE-EN 50288-2-1 - Multi-element metallic cables used in analogue and digital communication and control - Part 2-1: Sectional specification for screened cables characterised up to 100 MHz - Horizontal and building backbone cables
(Insulation) UNE-EN 50290-2-23 - Polyethylene for insulation.
(Sheath) UNE-EN 50290-2-27 - Halogen-free Z1 compound.
(Fire) UNE-EN 60754-1 (IEC 60754-1) - Halogen-free.
(Fire) UNE-EN 61034 (IEC 61034) - Low smoke emission.
(Fire) UNE-EN 60754-2 (IEC 60754-2) - Low corrosivity of smoke.
(Fire) UNE-EN 60332-1 (IEC 60332-1) - Flame-retardant.
(Directives) 2011/65/EU - RoHS Directive (No use of toxic products).
(Directives) 2014/35/EU - Low Voltage Products European Directive.
(System) ISO/IEC 11801 Edition 2 - CLASSE D - Information technology -- Generic cabling.
(System) UNE-EN 50173-1 - Information technology - Generic cabling systems - Part 1: General requirements.
Fill in the following fields to request the cable technical sheet in PDF format and the Declaration of Performance (DOP)