CONDEFLEX RZ1MZ1-K (AS+) 0,6/1kV

ARMOURED  |  HALOGEN-FREE

CONDEFLEX RZ1MZ1-K (AS+) 0,6/1kV

Construction

Conductor: Flexible stranded copper wire. Class 5 acc/. UNE-EN 60228.
Insulation: UNE-EN 21123-4 - XLPE polyethylene type DIX 3 according to HD 603-1.
Identification: HD 308 S2
Assembly: Concentrically assembled insulated conductors.
Filling sheath: UNE-EN 21123-4 - Polyolefin LSZH.
Armour: Steel wire armour (SWA).
Outer cover: UNE-EN 21123-4 - Halogen-free polyolefin (type DMZ-E).
Color: Orange

CONDEFLEX RZ1MZ1-K (AS+) 0,6/1kV
RoHS RoHS
CPR Compilant CPR Compilant
Halogen free Halogen free
Flexible cable Flexible cable
Low smoke opacity Low smoke opacity
Low gas corrosiveness Low gas corrosiveness
Fire retardant Fire retardant
Flame retardant Flame retardant
Mechanical protection Mechanical protection
Fire resistant Fire resistant

Technical data / Regulations

CPR classification: Eca
Operating voltage: 0,6/1KV
Test voltage: 3.500 V C.A. 5 min.
Operating temperature: -40...+90ºC (250ºC / 5 segundos en cortocircuito)
Standards:
(Construction) UNE-EN 21123-4 (IEC 60502) - Power cables for industrial use 0,6/1kV. Cross-linked polyethylene insulation (XLPE) and polyolefin sheath.
(Insulation) EN 50363-1 - Cables with intrinsic resistance to fire for use in safety circuits.
(Fire) UNE-EN 60754-1 (IEC 60754-1) - Halogen-free.
(Fire) UNE-EN 61034 (IEC 61034) - Low smoke emission.
(Fire) EN 50362, IEC 60331-1 (for Ø > 20mm) - Intrinsic resistance: PH120 (120 minutes at 840 °C).
(Fire) EN 50200, IEC 60331-2 (para Ø < 20mm) - Intrinsic resistance: PH90 (90 minutes at 840°C).
(Fire) UNE-EN 50575 - CPR
(Fire) UNE-EN 60754-2 (IEC 60754-2) - Low corrosivity of smoke.
(Fire) UNE-EN 60332-1 (IEC 60332-1) - Flame-retardant.
(Fire) UNE-EN 60332-3 (IEC 60332-3) Cat C - Fire retardant.

Observations

The armor of single-core cables is made of aluminum wires.
According to REBT 2002, it is suitable for the following installations:
ITC-BT 07 Underground distribution networks.
ITC-BT 09 Underground power networks for outdoor lighting installations.
ITC-BT 20 Indoor installations or receiving stations.
ITC-BT 29 Premises with risk of fire or explosion.

Allowable aid intensities for non-buried installations, with ambient temperature of 30° (UNE-HD 60364-5-52)

Applications

Flexible cable for the transport and distribution of electrical energy in fixed installations, protected or not, where intrinsic fire resistance is required. Especially designed for installations in public places where a safe reaction of the cable is required in case of fire, with low smoke opacity and minimizing the harmful effects of corrosive gas inhalation.
Suitable for indoor and outdoor installations (requiring UV protection), on outdoor supports, in tubes or direct burial. With a steel wire armour as mechanical protection.