Conductor: Flexible stranded copper wire. Class 5 acc/. UNE-EN 60228.
Insulation: UNE-EN 50290-2-26 - Halogen-free compound type Z1.
Identification: Color code A.3 according to UNE 212016.
Assembly: Pairs
Protector: Polyeste tape.
Individual Shielding Al/Pet: Aluminium/Polyester Tape.
Overall Shielding Al/Pet: Aluminium/Polyester Tape.
Individual Drain wire: Stranded tinned copper wire acc/. UNE-13602
Overall Drain wire: Stranded tinned copper wire acc/. UNE-13602
Outer cover: UNE-EN 50290-2-27 - Halogen-free compound type Z1.
Color: Grey RAL-7032
CPR classification: Eca
Operating voltage: 250V
Test voltage: 1000 V
Operating temperature: -5... +70ºC
Standards:
(Construction) UNE 212016 - Metallic cables with multiple elements used for data transmission for voltages below or equal to 250 V.
(Insulation) UNE-EN 50290-2-26 - Halogen-free compound type Z1.
(Sheath) UNE-EN 50290-2-27 - Halogen-free compound type Z1.
(Fire) UNE-EN 50575 - CPR
(Fire) UNE-EN 60754-2 (IEC 60754-2) - Low corrosivity of smoke.
(Fire) UNE-EN 61034 (IEC 61034) - Low smoke emission.
(Fire) UNE-EN 60754-1 (IEC 60754-1) - Halogen-free.
(Fire) UNE-EN 60332-1 (IEC 60332-1) - Flame-retardant.
(Directives) 2011/65/EU - RoHS Directive (No use of toxic products).
(Directives) 2014/35/EU - Low Voltage Products European Directive.
Flexible cables for data transmission, in pairs, for both analogue and digital signals, in computer applications, electronic control equipment, small machines for offices, scales, etc... With a good protection against electromagnetic interference thanks to the individual aluminium/polyester shielding per pair. With special fire characteristics that combine flame retardant features and a low heat emission with very low emission of smoke and hazardous gases.
Cables suitable for installation in dry or humid places. Mainly for fixed installations or with occasional movement.
Fill in the following fields to request the cable technical sheet in PDF format and the Declaration of Performance (DOP)